Southeastern Automation Product Sheet

HART PRODUCTS

HART® Field Communicator (375)
A portable intrinsically safe communicator that supports all their fieldbus devices. The result is the universal, user upgradeable, intrinsically safe, rugged and reliable 375 Field Communicator. The 375 Field Communicator is designed to support all HART® and all FOUNDATION™ fieldbus devices from all vendors.
Data Sheet

In-Situ Oxygen Analyzer - Hi-Temp 2-Wire HART® Smart (550-1600C) (5081FG)
Traditional in situ oxygen flue gas analyzers utilize zirconium oxide sensors to measure excess oxygen in process flue gas. These zirconium oxide sensors use a principle of operation based on the Nernst equation. This principle requires that the sensor cell be maintained at a high operating temperature using a heater that is powered via the analyzer's electronics. Many operators of combustion processes have applications that involve hazardous gases in the process itself or in the ambient gases in the area where the analyzer's electronics are installed. These operators are often concerned that the cell heater can serve as an ignition source to these hazardous gases inside the process or that the electronics can provide ignition to hazardous process or ambient gases that may be present. As a result of these concerns, these users must purchase oxygen analyzers with costly protection features. In addition, traditional in situ oxygen analyzers use metallic alloys that are also limited to temperatures in the range of 701°C (1300°F). This process temperature limitation prohibits the analyzer from being inserted close to the actual combustion process. Many operators prefer to measure flue gas oxygen close to the furnace or radiant section for a more representative O2 measurement. Improved analyzer accuracy can often result in significant fuel savings or improved process throughput.
Data Sheet

In-Situ Oxygen Transmitter - Explo-Proof w/FOUNDATION™ fieldbus (Oxymitter 5000)
The Oxymitter 5000 In Situ Oxygen Transmitter with FOUNDATION fieldbus Communications is the world's first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement with an explosion-proof rating. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency. Ideal for boilers, process heaters, kilns and reheat furnaces.
Data Sheet

In-Situ Oxygen Transmitter - w/FOUNDATION™ fieldbus (Oxymitter 5000)
The Oxymitter 5000 In Situ Oxygen Transmitter with FOUNDATION fieldbus Communications is the world's first in situ, zirconium oxide-based oxygen transmitter for flue gas measurement. These oxygen measurements can be used in a control system or by a boiler operator to fine tune burner fuel/air ratios for maximum efficiency. Ideal for boilers, process heaters, kilns and reheat furnaces.
Data Sheet
PowerVue Drive - Retrofit Kit 4X5 or 8X14 (PVD468R)
Hagan Pneumatic Power Positioners have defined the standard of excellence in fan and damper actuation for more than 70 years. These actuators convert the linear motion from a pneumatic piston into an 80° rotation of a drive arm. With few moving parts, the pneumatic power positioner remains the simplest, most reliable and most cost-effective method of actuation. Torque ranges are offered from 400 ft-lbs to 4,600 ft.-lbs.
Data Sheet
Process Analyzer - NDIR/Oxygen/Thermal Conductivity (BINOS 100 2M)
The BINOS® 100 2M Dual-Channel Gas Analyzer, as a member of the BINOS 100 Gas Analyzer Series, combines one IR sensor with another IR sensor, a thermal conductivity detector, an electrochemical or paramagnetic oxygen sensor in a 1/2 19" housing. Other possible combinations include two paramagnetic oxygen sensors, one oxygen sensor with a thermal conductivity detector or two thermal conductivity detectors.
Data Sheet
Process Analyzer - NDIR/Oxygen/Thermal Conductivity (BINOS 100 F)
The BINOS 100 F combines infrared (NDIR), paramagnetic (PO2 or electrochemical (EO2 oxygen sensors and thermal conductivity (TC) measurement as a single or dual channel instrument. The TC channel allows cross interference compensation for up to three externally measured gases. Internal sample handling options include a sample gas pump, fine-dust filter with a throttle, flow indicator and autocalibration solenoid valve block. For installation in hazardous areas, the BINOS 100 F can be equipped with a pressurization system according to CENELEC EN 50016 (EExp) for Ex Zone 1 or Ex Zone 2, touch screen and impact tested security glass front panel cover (EN 50014).
Data Sheet
Process Analyzer - Transmitter - NDIR/O2/TC - Explo-Proof (CAT 100)
Rosemount Analytical's CAT 100 Continuous Gas Analyzer Transmitter with optional FOUNDATION™ fieldbus communications, delivers multi-component, multi-technology gas analysis in an explosion-proof enclosure. The CAT 100 provides superior performance and has been designed for precise, continuous gas measurements in a variety of applications. The CAT 100 is housed in a Class I, Zone I (IIB) + H2-approved transmitter-style enclosure that can be field mounted in the harshest environmental conditions. The enclosure can be mounted near the process without requiring ambient controls or costly and space-consuming shelters. This feature greatly reduces installation and utility costs while vastly improving process efficiency.
Data Sheet
Process Analyzer - Transmitter (CAT 200)
Rosemount Analytical, the world leader in process gas analyzers, offers the CAT 200 multi-component, multi-technology Continuous Gas Analyzer Transmitter with explosion-proof packaging. The CAT 200 provides superior performance and has been designed for precise, continuous gas measurements in a variety of applications.
Data Sheet
Process Multi-Method/Channel Analyzer - Field Enclosure (NGA 2000 MLT 2
Rosemount Analytical's MLT series of NGA 2000 analyzers offer multi-component, multi-method analysis using infrared, ultraviolet, thermal conductivity, paramagnetic and electrochemical sensor technologies.
Data Sheet
Process Multi-Method/Channel Analyzer (NGA 2000 MLT 1)
Rosemount Analytical's NGA 2000 MLT Series of gas analyzers offers multi-component, multi-method analysis using infrared, ultraviolet, thermal conductivity, paramagnetic and electrochemical sensor technologies. The NGA 2000 MLT 1 Multi-Component Gas Analyzer measures up to four gas components by combining the different technologies into one unit.
Data Sheet

Emerson Combustion Products