Southeastern Automation Product Sheet

Digital Indicators / Alarms

 

 


Model 900

Model 901, 902, 903, 904

Model 910

Model 911

NEMA4X Digital Indicators
Description / Features

  • Model 900 - 101 segment Bargraph Display
    110 VAC or 220 VAC primary power - Supplies 24 VDC operating voltage to any loop powered transmitter.
  • Model 901 - Digital Display
    110 VAC or 220 VAC primary power - Supplies 24 VDC operating voltage to any loop powered transmitter.
  • Model 902 - Digital Display with Integral PM-1000B CLT Transmitter
    110 VAC or 220 VAC primary power - Designed for use with PROMAG CLT Transmitters. (CLT-x25 must be ordered with remote option). Supplies 24 VDC operating voltage to integral PM-1000B. Only 3 wires required between CLT sensing element and Model 902 Indicator.
  • Model 903 - Digital Display with Dual Alarms
    110 VAC or 220 VAC primary power -   Supplies 24 VDC operating voltage to any loop powered transmitter. Front Panel Alarm Lamps. Alarms may be set as High / Low, and adjusted from the front panel.
  • Model 904 - Digital Display with Dual Alarms / Integral PM-1000B CLT Transmitter
    110 VAC or 220 VAC primary power -   Supplies 24 VDC operating voltage to  to integral PM-1000B. (CLT-x25 must be ordered with remote option). Only 3 wires required between CLT sensing element and Model 904 Indicator. Front Panel Alarm Lamps. Alarms may be set as High / Low, and adjusted from the front panel.
  • Model 910 - 3 1/2 Digit LCD Display
    110 VAC or 220 VAC primary power - Supplies 24 VDC operating voltage to any loop powered transmitter. Features compact size. ( approx 8" high by 6" wide by 5" deep)
  • Model 911 - 3 1/2 Digit LCD Display / Auxillary 4/20 mA Output Terminals
    110 VAC or 220 VAC primary power -   Supplies 24 VDC operating voltage to any loop powered transmitter.    Auxillary output terminals.
Model PDI-1101

Model PDI-1100T

Model PDI-1100PS

Explosion - Proof  Digital Indicators 
(suitable for use in Cl I, Div 1, Grps B, C, and D environments)

Description / Features

  • Model PDI-1101   Loop Powered 3 1/2 Digit LCD
    Terminal Strip field wiring connection.  1/2" High Display. Minimal Loop Voltage Drop (2.2 VDC Typical)
  • Model PDI-1100T   Loop Powered 3 1/2 Digit LCD with  Integral PM-1000B Transmitter
    Designed for use with PROMAG  CLT-x25 Liquid Level Transmitters. CLT must be ordered with Remote Option.   1/2" High Display. Minimal Loop Voltage Drop (2.2 VDC Typical)
  • Model PDI-1100PS  -  3 1/2 Digit LCD with   Integral Loop Power Supply
    110 VAC or 220 VAC primary power - Supplies 24 VDC operating voltage to any loop powered transmitter. 1/2" High Display. Minimal Loop Voltage Drop (2.2 VDC Typical)

ProMag Products