Southeastern Automation Product Sheet


X-STREAM ANALYZERS

XS: O2 X-STREAM In Situ Oxygen Analyzer

The X-STREAM integrates an oxygen probe and field electronics into a single, compact package. The probe inserts directly into a flue gas duct to measure oxygen in combustion processes. No sampling system is required. A NEMA 4X, IP 66 Rosemount Analytical transmitter housing mounts directly to the probe and contains the transmitter's electronics, replacing common stand-alone field electronics. This integrated design minimizes the cost of installing separate probe cable, conduit and electronics. The X-STREAM electronics also require much less power to operate, reducing heat generated, and extending electronics life. The HART® communications with EDDL protocol provides a link into Emerson Process Management's PlantWeb® architecture. Setup, calibration and service diagnostics can be performed remotely with a HART 375 hand-held communicator, AMS or via a single or dual channel Xi enhanced interface. The Xi enhanced interface also carries advanced features such as automatic calibration, extended process temperature operation to 850°C (1562°F), Stoichiometer feature and programmable reference.

One-time Installation
The X-STREAM oxygen transmitter is easy to install. The probe tube can be threaded directly into an economical 2½" NPT thread or also use the more traditional flange mount. Adaptor flanges are available for most competitive probe mounts. Calibration and reference gas lines use ¼ inch ferrule fittings. AC line voltage directly powers the heater inside the probe and the transmitter electronics are loop-powered by the 2-wire 4-20mA signal. Once the initial installation is complete, the probe and its associated wiring and gas fittings never need to be removed.

  • AccuMax enhanced system performance
  • Accuracy ±0.75% of reading or ±0.05% oxygen
  • Signal stability of ±0.03% oxygen
  • Insensitive to process temperature changes ±0.02% from 100-700°C
  • Calibration validity of better than 0.02%
  • Adaptable to most existing oxygen probe installations
  • 2-wire, loop-powered electronics
  • HART communications standard
  • Extended process temperature range to 850°C (1562°F)
  • Advanced sensor diagnostics, including "calibration recommended"
  • Oxycore sensor core replacement in minutes
  • Stoichiometer feature measures oxygen deficiency during reducing conditions
  • Two-year sensing cell warranty
  • AMS/PlantWeb® compatible with EDDL

X-STREAM In Situ Oxygen Analyzer Data Sheet