` Rosemount Analytical Measurement PDF Files
USA SALES ONLY

Southeastern Automation, Inc.
PO Box 22820
Knoxville, TN 37933-0820
Phone: (865) 675-3080
Fax: (865) 675-3060
www.southeastern-automation.com

Southeastern Automation Product Sheet

ROSEMOUNT ANALYTICAL
MEASUREMENT DIVISION

Technical Information
Pressure Products
3051 1151 3095 2088
Level Products
3300 2110 5400 2120
5600 3051L 1151LT  
Flow Products
8721 8705 8711 8712D
8732C 8800CR 8800C 3095MFA
3451SFA 285 485  
Temperature Products
3144P 3244MV 3244MV with Profibus 644H
644R 244 244ER 848
Accessories
305 751 1195 752
1495 375 3420 248


Reference Material
Application Selection Guide
Product Technical Information
Pressure Products
Model 3051
3051 Pressure Transmitter Data Sheet Dimensional Drawing for 3051C
Dimensional Drawing for 3051H Integral Orifice Flowmeter Series Data Sheet
1199 Diaphragm Seal Systems Product Data Sheet Failure Modes, Effects and Diagnosis Analysis 3051S SIS
3051S Dinemsional Drawing 3051S Certifications
3051S Data Sheet 3051S Ordering Info
3051S Scalable Pressure, Flow, and Level Solutions 3051S Specs
3051T Dimensional Drawing 3051 HART Protocol C1 Option Configuration Data Sheet
Model 3051 Pressure Transmitter with HART protocol® Reference Manual 3051 Digital Pressure Transmitter Specifications
Rosemount 305 and 306 Integral Manifolds Data Sheet 3051 Pressure Transmitter with Profibus–PA Communications Protocol Manual
3051S Quick Install Guide 3051S Reference Manual
3051S Data Sheet 3051S Configuration Data Sheet
3051S Series Pressure Transmitter Family with FOUNDATION Fieldbus protocol 3051S Manual Suppliment - Installation
Compact Orifice Flowmeter Series Annubar® Flowmeter Series Data Sheet
Failure Modes, Effects and Diagnosis Analysis 3051S
Model 3095
3095 Dimensional Drawing 3095 MultiVariable™ Transmitter with MODBUS™ Protocol
3095 MultiVariable™ Mass Flow Transmitter 3095 HART Configuration Data Sheet
3095 MultiVariable™ Mass Flow Transmitter with HART® or FOUNDATION™ Fieldbus Protocol Manual 3095 MultiVariable Mass Flow Transmitter
3095 Configuration Data Sheet
Model 2088
2088 Absolute and Gage Pressure Transmitter 2088S Dimensional Drawing
2088 Configuration Data Sheet 2088, 2090P, and 2090F Pressure Transmitters Manual
2088 Specifications
Level Products
Model 3300
3300 Series Guided Wave Radar Level & Interface Transmitter 3300 Series Quick Installation Guide
3300 Technical Note 3300 Series Reference Manual
3300 Series Data Sheet 3300 Series Application & Configuration Data Sheet
3300 Mechanical Installation Drawing Rigid Twin Lead with endpiece 3300 Mechanical Installation Drawing Rigid Twin Lead without endpiece
3300 Mechanical Installation Drawing Flexible Twin Lead 3300 Mechanical Installation Drawing Rigid Single Lead
3300 Mechanical Installation Drawing Flexible Single Lead 3300 Mechanical Installation Drawing Coaxial Lead
3300 Mechanical Installation Drawing Rigid Single Lead Special Material 3300 Mechanical Installation Drawing Coaxial Lead Special Material
3300 Mechanical Installation Drawing Rigid Single Lead 3300 Mechanical Installation Drawing Coaxial Lead
Model 2110
2110 Reference Manual 2110 Data Sheet
2110 for Glue Level Control 2110 Hygienic Tank Overspill Measurement
2110 High Level Detection 2110 in Coolant / Lubricating Oils (Filtration)
2110 in Soft Drinks 2110 - Prevented Spills With Vibrating Fork Level Switch
2110 Application Data Sheet
Model 5400
5400 Brochure 5400 Series Two-wire Radar Level Transmitter Manual
5400 Series Two-wire Radar Level Transmitter with FOUNDATION™ Fieldbus Manual 5400 Series Data Sheet
5400 Series Quick Installation Guide 5400 Mechanical Installation Drawing
5400 Mechanical Installation Drawing Pipe Inst 5400 Mechanical Installation Drawing Bridle Inst
5400 Mechanical Installation Drawing Special Alloys 5400 Mechanical Installation Drawing Special Alloys Pipe Inst
5400 Mechanical Installation Drawing Special Alloys Bridle Inst 5400 Mechanical Installation Drawing Process Seal
5400 Mechanical Installation Drawing Rod Antenna
Model 2120
2120 Reference Manual 2120 Manual Supplement - Replacement and Calibration of Electronic Spare (PCB) Cassettes
2120 Data Sheet 2120 Low Level Alarm
2120 on Hazardous Chemicals 2120 Leakage Control on Double-Walled Tanks
2120 On Low Vessel Drain Duty 2120 Dimentional Drawing SQUIG
SIL Declaration of Conformity Functional safety according to IEC 61508
Model 5600
5600 Series Radar Level Transmitter Reference Manual 5600 Series Data Sheet
5600 Series Application and Configuration Data Sheet 5601 Brochure
Drawing - Flange Process Seal 5600 Mechanical Installation Drawing Process Seal
5600 Mechanical Installation Drawing Rod Antenna Drawing - Flange, Stainless Steel Centre Hole 034
5600 Mechanical Installation Drawing Cone Antenna 5600 Mechanical Installation Drawing, Steel Pipe
5600 Mechanical Installation Drawing, 2210 Display Unit 5600 Electrical Installation Drawing, 2210 Display Unit
5600 Electrical Installation Drawing, 2210 DU Temp Conn 5600 Mechanical Installation Drawing, Bridle
5600 Mechanical Installation Drawing, Cleansing Device Mechanical Installation Drawing, Flange Ball T38-W Welding
Mechanical Installation Drawing, Flange Ball T30 5600 Mechanical Installation Drawing, Parabolic Antenna
Model 3051L
3051 Data Sheet 3051Dimentional Drawings
3051L Outline Installation Drawing 3051 Data Sheet - Product Offering
3051 Ordering Information 3051 Data Sheet
3051 Specs 3051 HART Protocol C1 Option Configuration Data Sheet
3051 Manual 3051 Specs
Model 1151 LT
1151 Data Sheet 1151 Dimensional Drawings
1151LT Dimensional Drawing 1151 Manual Rev AA
1151 Specs 1151 Configuration Data Sheet
1151 Manual Rev BA
Flow Products
Model 8721
8706 & 8707 Specs 8712 D/H and 8732C Configuration Data Sheet
8721 Data Sheet 8721 - Sanitary Gasket Material Selection Guide
8700 Manual 8700 Data Sheet
8705 Outline Installation Drawing - 1.5 to 4" Integrally Mounted Transmitter 8705 Outline Installation Drawing - 0.5 and 1" Integrally Mounted Transmitter
8705 Outline Installation Drawing - 10 to 36" Integrally Mounted Transmitter 8705 Outline Installation Drawing - 6 and 8" Integrally Mounted Transmitter
Material Selection Guide
Model 8705
8706 & 8707 Specs 8700 Manual
8700 Series Data Sheet 8705 Outline Installation Drawing - 1.5 to 4" Integrally Mounted Transmitter
8705 Outline Installation Drawing - 0.5 and 1" Integrally Mounted Transmitter 8705 Outline Installation Drawing - 10 to 36" Integrally Mounted Transmitter
8705 Outline Installation Drawing - 6 and 8" Integrally Mounted Transmitter Material Selection Guide
Model 8711
8711 Specs 8700 Manual
8700 Data Sheet 8711 Outline Installation Drawing for 0.5 and 8" Wafer Flowtubes
Material Selection Guide
Model 8712D
8712D Reference Manual Manual Supplement - Upgrading the Rosemount 8712C to a 8712D
8712D Technical Data - Introducing the Latest Improvement to the Rosemount 8712 Magnetic Flowmeter 8712D & 8700 Quick Installation Guide
8712 D/H and 8732C Configuration Data Sheet 8712C/U/H Manual
8700 Data Sheet 8712D Failure Modes, Effects and Diagnostic Analysis
8712 Dimensional Drawing Material Selection Guide
Model 8732C
8712 D/H and 8732C Configuration Data Sheet 8732C Manual
8732C Specs 8700 Data Sheet
8732C Failure Modes, Effects and Diagnostic Analysis 8732C Outline Installation Drawing
Material Selection Guide
Model 8800CF/CR
8800C and 8800A Manual 8800C Specs
8800C v210 Failure Modes, Effects and Diagnostic Analysis 8800C Installation Drawing
8800 Installation Drawing 8800 Installation Drawing
8800C Quick Installation Guide 8800CR Application Note - Reducer Vortex Minimizes Cost and Project Risk
8800 Application Note - ReducerTM Vortex Minimizes Cost and Risk on Refinery Upgrade Project 8800 Application Note - ReducerTM Vortex Saves $1121 on Steam Flow Measurement at Chemical Plant
8800C Data Sheet 8800 Application Note - Reducer Vortex Minimizes Project Risk and Saves Over $500 per Flow Point
Model 3095 MFA
485 Annubar® Flanged Assembly Quick Installation Guide 485 Annubar® Flange-Lok Assembly Quick Installation Guide
485 Annubar® Pak-Lok Assembly Quick Installation Guide 485 Annubar® Flanged Flo-Tap Assembly Quick Installation Guide
485 Annubar® Threaded Flo-Tap Assembly Quick Installation Guide Annubar® Flowmeter Series Manual
Averaging Pitot Tube Specification Guide Annubar® Flowmeter Series Data Sheet
Annubar Flowmeter Series HART Configuration Data Sheet
Model 3051 SFA
485 Annubar® Flanged
Assembly Quick Installation Guide
485 Annubar® Flange-Lok Assembly Quick Installation Guide
485 Annubar® Pak-Lok Assembly Quick Installation Guide 485 Annubar® Flanged Flo-Tap Assembly Quick Installation Guide
485 Annubar® Threaded Flo-Tap Assembly Quick Installation Guide Annubar® Flowmeter Series Manual
Averaging Pitot Tube Specification Guide Annubar® Flowmeter Series Data Sheet
Annubar Flowmeter Series HART Configuration Data Sheet
Model 285
Dimensional Drawing for 285 Sensor Size 1 Annubar Pak-Lok Mounting Type Dimensional Drawing for 285 Sensor Size 1 Annubar Duct Mount w/o Compression Fitting
Dimensional Drawing for 285 Sensor Size 1 Annubar Duct Mount with Compression Fitting Dimensional Drawing for 285 Sensor Size 2 Annubar Pak-Lok Mounting Type
Dimensional Drawing for 285 Sensor Size 2 Annubar Duct Mount w/o Compression Fitting Dimensional Drawing for 285 Sensor Size 2 Annubar Duct Mount with Compression Fitting
285 Manual 285 Data Sheet
285 Annubar® Pak-Lok Assembly Quick Installation Guide 285 Annubar® Duct Mount Quick Installation Guide
285 Annubar Primary Element Configuration Data Sheet
Model 485
485 Annubar® Flanged
Assembly Quick Installation Guide
485 Annubar® Flange-Lok Assembly Quick Installation Guide
485 Annubar® Pak-Lok Assembly Quick Installation Guide 485 Annubar® Flanged Flo-Tap Assembly Quick Installation Guide
485 Annubar® Threaded Flo-Tap Assembly Quick Installation Guide Annubar® Flowmeter Series Manual
Averaging Pitot Tube Specification Guide 485 Annubar Flow Handbook
Annubar® Flowmeter Series Data Sheet Annubar Flowmeter Series HART Configuration Data Sheet
Temperature Products
Model 3144P
3144P Drawing 3144P Data Sheet
3144P Configuration Data Sheet Compatibility matrix -- Model 3144, 3244MV, and 3144P HART Temperature Transmitters
Model 3244MV
3144 & 3244 Installation Drawing 3244MV Data Sheet
3244MV Manual Foundation™ Fieldbus Blocks
3244MV Configuration Data Sheet
Model 3244MV with Profibus
3144 & 3244 Installation Drawing 3244MV with Profibus Manual
3244MV with Profibus Data Sheet Profibus Device Description Installation Procedure
Model 644
644 Configuration Data Sheet 644 Manual
644 Data Sheet 644H & 244EH Dimensional Drawing
644H Brochure 644R & 244ER Dimensional Drawing
Model 244ER
244EH and 244ER Configuration Data Sheet Manual Supplement - Important Model 848T Installation Considerations
244ER Data Sheet 244EH & 244ER Specs
Manual Supplement for 244EH & 244ER 644R & 244ER Dimensional Drawing
Model 848
848 Dimensional Drawing Manual Supplement - Important Model 848T Installation Considerations
848T with FOUNDATION™ Fieldbus Manual 848T with FOUNDATION™ Fieldbus Data Sheet
Foundation™ Fieldbus Blocks
Accessories
Model 305
305RC Integral Manifold Installation Drawing 305RM Integral ManifoldInstallation Drawing
305RT Integral Manifold Installation Drawing 306BT Pressure Manifold Installation Drawing
306RT Manifold Installation Drawing 305 & 306 Integral Manifolds Data Sheet
Model 751
751 Manual 751 Data Sheet
751 Dimensional Drawing
Model 1195
1195 Data Sheet 1195 Outline Installation Drawing
Model 752
752 Manual 752 Fieldbus Manual
752 Dimensional Drawing
Model 1495
1595 Manual 1595 Data Sheet
405 & 1595 Flow Test Data Book & Flow Handbook Wet Gas Flow Measurement with Conditioning Orifice Meter Flow Test Data Book & Flow Handbook
1495 Dimensional Drawing for Paddle Style Orifice Plate Primary 1495 Dimensional Drawing for Paddle Style Spiral Finish Orifice Plate Primary
1495 Dimensional Drawing for Universal Style Orifice Plate Primary 1496 Dimensional Drawing for Orifice Flange Union
1497 Dimensional Drawing for Raised Face, Weld Neck Orifice Meter Section 1497 Dimensional Drawing for Ring Joint, Weld Neck Orifice Meter Section
1497 Dimensional Drawing for Raised Face, Slsip-On Orifice Meter Section 1495 Orifice Plate 1496 & 1497 Installation & Operation Manual
1495, 1496, and 1497 Data Sheet 1595 Configuration Data Sheet
1195 & 1495 Configuration Data Sheet
Model 375
375 Brochure
Model 3420
3420 Manual 3420 Outline Installation Drawing
Using the Rosemount 3420 for Tank Farm Monitoring 3420, Application Examples. Distillation/Fractionation Columns & Reactors
Using the Rosemount 3420 for Bulk Inputs and Skid Mounted Monitoring Solutions Chemical Reactor Shutdown is Avoided with Rosemount 848T and 3420
Model 248
248 Manual 248 Data Sheet
248 Quick Installation Guide 248 Configuration Data Sheet

Rosemount Measurement Division Products

Principals Listing Page